Evaluation of the short- and long-term effectiveness and safety of fully covered self-expandable metal stents for drainage of pancreatic fluid collections: results of a Spanish nationwide registry

Fecha de publicación:

Autores de IdISBa

Autores ajenos a IdISBa

  • Vazquez-Sequeiros, E
  • Baron, TH
  • Perez-Miranda, M
  • Sanchez-Yague, A
  • Gornals, J
  • Gonzalez-Huix, F
  • de la Serna, C
  • Angel Gonzalez Martin, Juan
  • Gimeno-Garcia, AZ
  • Marra-Lopez, C
  • Castellot, A
  • Alberca, F
  • Fernandez-Urien, I
  • Ramon Aparicio, Jose
  • Luisa Legaz, Maria
  • Sendino, O
  • Loras, C
  • Carlos Subtil, Jose
  • Nerin, J
  • Perez-Carreras, M
  • Diaz-Tasende, J
  • Perez, G
  • Repiso, A
  • Alvarez, A
  • Rodriguez, S
  • Miguel Esteban, Jose
  • Juzgado, D
  • Albillos, A
  • Spanish Grp FCSEMS Pancreas Collec

Abstract

Background and Aims: Initial reports suggest that fully covered self-expandable metal stents (FCSEMSs) may be better suited for drainage of dense pancreatic fluid collections (PFCs), such as walled-off pancreatic necrosis. The primary aim was to analyze the effectiveness and safety of FCSEMSs for drainage of different types of PFCs in a large cohort. The secondary aim was to investigate which type of FCSEMS is superior. Methods: This was a retrospective, noncomparative review of a nationwide database involving all hospitals in Spain performing EUS-guided PFC drainage. From April 2008 to August 2013, all patients undergoing PFC drainage with an FCSEMS were included in a database. The main outcome measurements were technical success, short-term (2 weeks) and long-term (6 months) effectiveness, adverse events, and need for surgery. Results: The study included 211 patients (pseudocyst/walled-off pancreatic necrosis, 53%/47%). The FCSEMSs used were straight biliary (66%) or lumen-apposing (34%). Technical success was achieved in 97% of patients (95% confidence interval [CI], 93%-99%). Short-term- and long-term clinical success was obtained in 94% (95% CI, 89%-97%) and 85%(95% CI, 79%-89%) of patients, respectively. Adverse events occurred in 21% of patients (95% CI, 16%-27%): infection (11%), bleeding (7%), and stent migration and/or perforation (3%). By multivariate analysis, patient age (> 58 years) and previous failed drainage were the most important factors associated with negative outcome. Conclusions: An FCSEMS is effective and safe for PFC drainage. Older patients with a history of unsuccessful drainage are more likely to fail EUS-guided drainage. The type of FCSEMS does not seem to influence patient outcome.

Datos de la publicación

ISSN/ISSNe:
0016-5107, 1097-6779

Gastrointestinal Endoscopy  MOSBY-ELSEVIER

Tipo:
Article
Páginas:
450-450