Análisis de resultados del Programa de Control de Calidad Externo de carga viral del VIH-1, del VHC y del VHB. Año 2013.

Fecha de publicación:

Autores de IdISBa

Autores ajenos a IdISBa

  • Orta Mira N
  • Del Remedio Guna Serrano M
  • Latorre Martínez JC
  • Medina González R
  • Rosario Ovies M
  • Poveda M
  • Gimeno Cardona C

Grupos de Investigación

Abstract

Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2013 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (25% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 78% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up.

Datos de la publicación

ISSN/ISSNe:
0213-005X, 1578-1852

Enfermedades Infecciosas Y Microbiologia Clinica  EDICIONES DOYMA S A

Tipo:
Abstract of Published Item
Páginas:
9-14
PubMed:
26320990

Citas Recibidas en Web of Science: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Carga viral, Control de calidad externo, External quality control, HBV, HCV, HIV-1, Intercomparación, Proficiency, VHB, VHC, VIH-1, Viral load

Campos de Estudio

Cita

Compartir