Mechanical power is not associated with mortality in COVID-19 mechanically ventilated patients
Fecha de publicación:
Autores de IdISBa
Autores ajenos a IdISBa
- Barbeta, E
- Barreiros, C
- Forin, E
- Guzzardella, A
- Motos, A
- Fernández-Barat, L
- Gabarrús, A
- Ceccato, A
- Ferrer, R
- Riera, J
- Peñuelas, O
- Lorente, JA
- de Gonzalo-Calvo, D
- Gonzalez, J
- Amaya-Villar, R
- Añón, JM
- Balan, A
- Barberà, C
- Barberán, J
- Blandino, A
- Boado, MV
- Bustamante-Munguira, E
- Caballero, J
- Cantón-Bulnes, ML
- Carbajales, C
- Carbonell, N
- Catalán-González, M
- Franco, N
- Galbán, C
- Gumucio-Sanguino, VD
- de la Torre, MD
- Díaz, E
- Estella, A
- Gallego, E
- Gómez, JM
- Huerta, A
- García, RNJ
- Loza-Vázquez, A
- Marin-Corral, J
- Delgado, MCM
- Martínez, A
- Martínez, I
- Lopez, J
- Albaiceta, GM
- Nieto, MT
- Peñasco, Y
- Pérez-García, F
- Ricart, P
- Rodríguez, A
- Sagredo, V
- Sánchez-Miralles, A
- Sancho, S
- Roche-Campo, F
- Solé-Violan, J
- Tamayo, L
- Trenado, J
- Ubeda, A
- Valdivia, LJ
- Vidal, P
- Vallverdú, J
- Torres, A
- CIBERESUCICOVID Project Investigators COV20 00110 ISCIII
Grupos de Investigación
Abstract
BackgroundThe relative contribution of the different components of mechanical power to mortality is a subject of debate and has not been studied in COVID-19. The aim of this study is to evaluate both the total and the relative impact of each of the components of mechanical power on mortality in a well-characterized cohort of patients with COVID-19-induced acute respiratory failure undergoing invasive mechanical ventilation. This is a secondary analysis of the CIBERESUCICOVID project, a multicenter observational cohort study including fifty Spanish intensive care units that included COVID-19 mechanically ventilated patients between February 2020 and December 2021. We examined the association between mechanical power and its components (elastic static, elastic dynamic, total elastic and resistive power) with 90-day mortality after adjusting for confounders in seven hundred ninety-nine patients with COVID-19-induced respiratory failure undergoing invasive mechanical ventilation.ResultsAt the initiation of mechanical ventilation, the PaO2/FiO2 ratio was 106 (78; 150), ventilatory ratio was 1.69 (1.40; 2.05), and respiratory system compliance was 35.7 (29.2; 44.5) ml/cmH2O. Mechanical power at the initiation of mechanical ventilation was 24.3 (18.9; 29.6) J/min, showing no significant changes after three days. In multivariable regression analyses, mechanical power and its components were not associated with 90-day mortality at the start of mechanical ventilation. After three days, total elastic and elastic static power were associated with higher 90-day mortality, but this relationship was also found for positive end-expiratory pressure.ConclusionsNeither mechanical power nor its components were independently associated with mortality in COVID-19-induced acute respiratory failure at the start of MV. Nevertheless, after three days, static elastic power and total elastic power were associated with lower odds of survival. Positive end-expiratory pressure and plateau pressure, however, captured this risk in a similar manner.
Datos de la publicación
- ISSN/ISSNe:
- 2110-5820,
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 39998751
Annals of Intensive Care SPRINGER HEIDELBERG
Citas Recibidas en Web of Science: 8
Documentos
- No hay documentos
Filiaciones
Keywords
- Mechanical power; COVID-19; Mechanical ventilation; Respiratory failure
Campos de Estudio
Cita
Barbeta E; Barreiros C; Forin E; Guzzardella A; Motos A; Fernández Barat L; Gabarrús A; Ceccato A; Ferrer R; Riera J; Peñuelas O; Lorente JA; de Gonzalo Calvo D; Gonzalez J; Amaya Villar R; Añón JM; Balan A; Barberà C; Barberán J; Blandino A; Boado MV; Bustamante Munguira E; Caballero J; Cantón Bulnes ML; Carbajales C; Carbonell N; Catalán González M; Franco N; Galbán C; Gumucio Sanguino VD; de la Torre MD; Díaz E; Estella A; Gallego E; Gómez JM; Huerta A; García RNJ; Loza Vázquez A; Marin Corral J; Delgado MCM; Martínez A; Martínez I; Lopez J; Albaiceta GM; Nieto MT; Novo MA; Peñasco Y; Pérez García F; Ricart P; Rodríguez A; Sagredo V; Sánchez Miralles A; Sancho S; Roche Campo F; Socias L; Solé Violan J; Tamayo L; Trenado J; Ubeda A; Valdivia LJ; Vidal P; Barbé F; Vallverdú J; Torres A; CIBERESUCICOVID Project Investigators COV20 ISCIII 00110. Mechanical power is not associated with mortality in COVID-19 mechanically ventilated patients. Annals of Intensive Care. 2025. 15 (1):
Portal de investigación