A Real-World Study Comparing Advanced Hybrid Closed-Loop Systems During Pregnancy in Women with Type 1 Diabetes
Fecha de publicación:
Fecha Ahead of Print:
Autores de IdISBa
Autores ajenos a IdISBa
- Quirós, C
- Wägner, AM
- Azriel, S
- Soldevila, B
- Beato-Vibora, PI
- Arranz, MH
- Nattero, L
- Picón-Cesar, MJ
- Climent, E
- Amigó, J
- Colomo, N
- Durán-Martinez, M
- Buesa, MA
- Megia, A
- Vinagre, I
- Guedes, BV
- Diaz-Soto, G
- Bandres, O
- Barquiel, B
- Tinocco, CL
- Márquez-Pardo, R
- Martinez-Brocca, MA
- Corcoy, R
- Piedra, M
- Román, AR
- Cuesta, M
- López-Gallardo, G
- Canino, MMG
- Bugatto, F
- Mendoza, LC
- Márquez, MDO
- Perea, V
Grupos de Investigación
Abstract
Objective: To compare maternal glucose metrics and pregnancy outcomes of three advanced hybrid closed-loop (aHCL) systems (MiniMed 780G (R), CamAPS (R) FX, and Tandem Control-IQ) in a real-world, multicenter cohort of pregnant women with type 1 diabetes.Research Design and Methods: Cohort study including 137 pregnant women with type 1 diabetes using aHCL from 27 hospitals in Spain. Participants were grouped according to the aHCL system used: 85 MiniMed 780G (62%), 38 CamAPS FX (27.7%), and 14 Control-IQ (10.2%). Maternal glucose metrics (HbA1c and time spent within [TIRp], below [TBRp], and above [TARp] the pregnancy-specific glucose range 3.5-7.8 mmol/L), as well as pregnancy outcomes, were analyzed. Adjusted models were applied to account for potential confounding factors.Results: No between-group differences in HbA1c levels were observed at baseline. By the third trimester, CamAPS FX and Control-IQ users had significantly lower HbA1c levels compared with the MiniMed 780G group (beta adjusted -4.77 mmol/mol, 95% confidence interval [CI] -7.40 to -2.13; and beta adjusted -4.79, 95% CI -8.53 to -1.06; respectively). In the second trimester, CamAPS FX was associated with a higher percentage of time in range (beta adjusted +5.88%, 95% CI 1.09 to 10.67) and a lower percentage of time above range (beta adjusted -6.36%, 95% CI -11.46 to -1.26) compared with MiniMed 780G, with no other significant differences observed in other trimesters. Both CamAPS FX and Control-IQ were associated with lower odds of large-for-gestational-age (LGA) infants (CamAPS FX: ORadjusted 0.25, 95% CI 0.08 to 0.77; Control-IQ: ORadjusted 0.10, 95% CI 0.01 to 0.99) compared with MiniMed 780G.Conclusions: In this multicenter observational study, CamAPS FX and Control-IQ users achieved better glycemic metrics and lower odds of delivering LGA infants compared with those using MiniMed 780G. These findings warrant investigation to confirm associations and inform individualized clinical decision-making in pregnant women with type 1 diabetes.
Datos de la publicación
- ISSN/ISSNe:
- 1520-9156, 1557-8593
- Tipo:
- Article
- Páginas:
- 327-340
- PubMed:
- 41005768
Diabetes Technology & Therapeutics MARY ANN LIEBERT, INC
Citas Recibidas en Web of Science: 7
Documentos
- No hay documentos
Filiaciones
Keywords
- advanced hybrid closed-loop; continuous glucose monitoring; HbA1c; maternal-fetal outcomes; pregnancy; type 1 diabetes
Portal de investigación