A Real-World Study Comparing Advanced Hybrid Closed-Loop Systems During Pregnancy in Women with Type 1 Diabetes

Fecha de publicación: Fecha Ahead of Print:

Autores de IdISBa

Autores ajenos a IdISBa

  • Quirós, C
  • Wägner, AM
  • Azriel, S
  • Soldevila, B
  • Beato-Vibora, PI
  • Arranz, MH
  • Nattero, L
  • Picón-Cesar, MJ
  • Climent, E
  • Amigó, J
  • Colomo, N
  • Durán-Martinez, M
  • Buesa, MA
  • Megia, A
  • Vinagre, I
  • Guedes, BV
  • Diaz-Soto, G
  • Bandres, O
  • Barquiel, B
  • Tinocco, CL
  • Márquez-Pardo, R
  • Martinez-Brocca, MA
  • Corcoy, R
  • Piedra, M
  • Román, AR
  • Cuesta, M
  • López-Gallardo, G
  • Canino, MMG
  • Bugatto, F
  • Mendoza, LC
  • Márquez, MDO
  • Perea, V

Grupos de Investigación

Abstract

Objective: To compare maternal glucose metrics and pregnancy outcomes of three advanced hybrid closed-loop (aHCL) systems (MiniMed 780G (R), CamAPS (R) FX, and Tandem Control-IQ) in a real-world, multicenter cohort of pregnant women with type 1 diabetes.Research Design and Methods: Cohort study including 137 pregnant women with type 1 diabetes using aHCL from 27 hospitals in Spain. Participants were grouped according to the aHCL system used: 85 MiniMed 780G (62%), 38 CamAPS FX (27.7%), and 14 Control-IQ (10.2%). Maternal glucose metrics (HbA1c and time spent within [TIRp], below [TBRp], and above [TARp] the pregnancy-specific glucose range 3.5-7.8 mmol/L), as well as pregnancy outcomes, were analyzed. Adjusted models were applied to account for potential confounding factors.Results: No between-group differences in HbA1c levels were observed at baseline. By the third trimester, CamAPS FX and Control-IQ users had significantly lower HbA1c levels compared with the MiniMed 780G group (beta adjusted -4.77 mmol/mol, 95% confidence interval [CI] -7.40 to -2.13; and beta adjusted -4.79, 95% CI -8.53 to -1.06; respectively). In the second trimester, CamAPS FX was associated with a higher percentage of time in range (beta adjusted +5.88%, 95% CI 1.09 to 10.67) and a lower percentage of time above range (beta adjusted -6.36%, 95% CI -11.46 to -1.26) compared with MiniMed 780G, with no other significant differences observed in other trimesters. Both CamAPS FX and Control-IQ were associated with lower odds of large-for-gestational-age (LGA) infants (CamAPS FX: ORadjusted 0.25, 95% CI 0.08 to 0.77; Control-IQ: ORadjusted 0.10, 95% CI 0.01 to 0.99) compared with MiniMed 780G.Conclusions: In this multicenter observational study, CamAPS FX and Control-IQ users achieved better glycemic metrics and lower odds of delivering LGA infants compared with those using MiniMed 780G. These findings warrant investigation to confirm associations and inform individualized clinical decision-making in pregnant women with type 1 diabetes.

Datos de la publicación

ISSN/ISSNe:
1520-9156, 1557-8593

Diabetes Technology & Therapeutics  MARY ANN LIEBERT, INC

Tipo:
Article
Páginas:
327-340
PubMed:
41005768

Citas Recibidas en Web of Science: 7

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • advanced hybrid closed-loop; continuous glucose monitoring; HbA1c; maternal-fetal outcomes; pregnancy; type 1 diabetes

Campos de Estudio

Compartir