The implementation of a streamlined TAVI patient pathway across five European countries: BENCHMARK registry
Fecha de publicación:
Fecha Ahead of Print:
Autores de IdISBa
Autores ajenos a IdISBa
- Saia F
- Lauck S
- Durand E
- Muir DF
- Spence M
- Vasa-Nicotera M
- Wood D
- Urbano-Carrillo CA
- Bouchayer D
- Iliescu VA
- Etienne CS
- Leclercq F
- Auffret V
- Asmarats L
- Di Mario C
- Veugeois A
- Maly J
- Schober A
- Nombela-Franco L
- Werner N
- Gómez-Hospital JA
- Mascherbauer J
- Musumeci G
- Meneveau N
- Meurice T
- Mahfoud F
- De Marco F
- Seidler T
- Leuschner F
- Joly P
- Collet JP
- Vogt F
- Di Lorenzo E
- Kuhn E
- McCalmont G
- Rakova R
- Wesselink W
- Kurucova J
- Hachaturyan V
- Lüske CM
- Bramlage P
- Frank D
- BENCHMARK Investigator Group
Grupos de Investigación
Abstract
Background Benchmark best practices have been shown to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI), but the impact in diverse health systems is unknown. Aims We evaluated the impact of Benchmark best practices implementation in Germany, Austria, France, Spain, and Italy. Methods International, multicentre registry of severe symptomatic aortic stenosis (AS) patients undergoing TAVI with a balloon-expandable valve, before and after Benchmark best practices implementation. Objectives were to reduce overall and intensive care unit (ICU) length of stay (LoS), and to document 30-day safety. Results A total of 890 patients were analysed in France, 454 in Spain, 362 in Germany, 300 in Italy, and 176 in Austria. Patients had the highest surgical risk in Germany (EuroSCORE II 6.8 +/- 7.3%) and lowest in Spain (3.8 +/- 2.6%). Austrian patients reported higher rates of prior myocardial infarction, severe pulmonary hypertension, and aortic valve-related symptoms at baseline. After the implementation of Benchmark best practices, the median hospital LoS was significantly reduced in France (5 vs. 3 days, p < 0.001), Spain (6 vs. 4, p < 0.001), Germany (9 vs. 6, p < 0.001), and Italy (7 vs. 5, p < 0.001); reductions in median ICU LoS were reported in France (1.1 vs. 0 days, p < 0.001), Spain (1.9 vs. 1, p < 0.001), and Germany (1 vs. 0.9, p = 0.004). Across all countries, 30-day safety outcomes were uncompromised and reduced rates of major vascular complications rates were observed in Germany (5.9 vs. 0.0%, p < 0.001). Conclusion The implementation of Benchmark best practices in diverse European healthcare systems resulted in reduced hospital and ICU LoS without compromising patient safety.
Datos de la publicación
- ISSN/ISSNe:
- 1861-0684, 1861-0692
- Tipo:
- Article
- Páginas:
- 1107-1119
- PubMed:
- 40261426
CLINICAL RESEARCH IN CARDIOLOGY SPRINGER HEIDELBERG
Citas Recibidas en Web of Science: 6
Documentos
- No hay documentos
Filiaciones
Keywords
- Aortic stenosis; Quality of care; Prospective registry; Transcatheter aortic valve implantation; TAVI; Clinical care
Campos de Estudio
Cita
Saia F; Lauck S; Durand E; Muir DF; Spence M; Vasa Nicotera M; Wood D; Urbano Carrillo CA; Bouchayer D; Iliescu VA; Etienne CS; Leclercq F; Auffret V; Asmarats L; Di Mario C; Veugeois A; Maly J; Schober A; Nombela Franco L; Werner N; Gómez Hospital JA; Mascherbauer J; Musumeci G; Meneveau N; Meurice T; Mahfoud F; De Marco F; Seidler T; Leuschner F; Joly P; Collet JP; Vogt F; Di Lorenzo E; Kuhn E; Disdier VP; McCalmont G; Rakova R; Wesselink W; Kurucova J; Hachaturyan V; Lüske CM; Bramlage P; Frank D; BENCHMARK Investigator G. The implementation of a streamlined TAVI patient pathway across five European countries: BENCHMARK registry. CLINICAL RESEARCH IN CARDIOLOGY. 2026. 115 (7): 1107-1119.
Portal de investigación