Abstract
BACKGROUND Risk stratification in Brugada syndrome (BrS) remains controversial. In this respect, the role of the electrophysiology study (EPS) has been a subject of debate. In some centers, it is common practice to use an implantable loop recorder (ILR) after a negative EPS to help in risk stratification. However, the diagnostic value of this approach has never been specifically addressed. OBJECTIVE The aim of this study was to describe the baseline characteristics and the main findings of a diagnostic workup strategy with an ILR after a negative EPS in BrS. METHODS We conducted a retrospective international registry including patients with BrS and negative EPS (ie, noninducible ventricular tachycardia or ventricular fibrillation) before ILR monitoring. RESULTS The study included 65 patients from 8 referral hospitals in The Netherlands, Spain, and the United Kingdom (mean age, 39 6 16 years; 72% male). The main indication for ILR monitoring was unexplained syncope/presyncope (66.2%). During a median follow-up of 39.0 months (Q1 25.0-Q3 47.6 months), 18 patients (27.7%) experienced 21 arrhythmic events (AEs). None of the patients died during follow-up. Bradyarrhythmias were the most common finding (47.6%), followed by atrial tachyarrhythmias (38.1%). Only 3 patients presented with ventricular arrhythmias. AEs were considered incidental in 12 patients (66.7%). In 11 patients (61.1%), AEs led to specific changes in treatment. CONCLUSION The use of ILR after a negative EPS in BrS is a safe strategy that reflected the high negative predictive value of EPS for ventricular arrhythmia in this syndrome. In addition, it allowed the detection of AEs in a significant proportion of patients, with therapeutic implications in most of them.
Datos de la publicación
- ISSN/ISSNe:
- 1547-5271, 1556-3871
- Tipo:
- Article
- Páginas:
- 1317-1324
- PubMed:
- 38458509
Heart Rhythm ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 5
Documentos
- No hay documentos
Filiaciones
Keywords
- Brugada syndrome; Electrocardiography; Implantable loop recorder; Sudden death; Ventricular arrhythmia
Campos de Estudio
Cita
García Izquierdo E; Scrocco C; Palacios Rubio J; Assaf A; Ripoll Vera T; Hernandez Betancor I; Ramos Ruiz P; Melero Pita A; Segura Domínguez M; Jiménez Sánchez D; Castro Urda V; Toquero Ramos J; Yap SC; Behr ER; Fernández Lozano I. Arrhythmia detection using an implantable loop recorder after a negative electrophysiology study in Brugada syndrome: Observations from a multicenter international registry. Heart Rhythm. 2024. 21 (8): 1317-1324.
Portal de investigación