Clinical recommendations for dry powder inhaler use in the management of COPD in primary care

Fecha de publicación:

Autores de IdISBa

Autores ajenos a IdISBa

  • Leving, MT
  • Bosnic-Anticevich, S
  • van Cooten, J
  • de Sousa, JC
  • Cvetkovski, B
  • Dekhuijzen, R
  • Dijk, L
  • Gardev, A
  • Gawlik, R
  • van Der Ham, I
  • Janse, Y
  • Lavorini, F
  • Maricoto, T
  • Meijer, J
  • Metz, B
  • Price, D
  • Schuttel, K
  • Stoker, N
  • Tsiligianni, I
  • Usmani, O
  • Emerson-Stadler, R
  • Kocks, JWH

Grupos de Investigación

Abstract

Over 1400 patients using dry powder inhalers (DPIs) to deliver COPD maintenance therapies were recruited across Europe and Australia. Their peak inspiratory flow (PIF) was measured, inhaler technique was observed, and adherence to treatment assessed. From relating the findings with patient health status, and thereby identifying critical errors, key clinical recommendations for primary care clinicians were determined, namely - measure PIF before prescribing a DPI to ensure inhalation manoeuvre ability is well-matched with the device. Some patients could benefit from inhalation training whereas others should have their DPI changed for one better suited to their inspiratory ability or alternatively be prescribed an active device (such as a soft mist inhaler or pressurized metered dose inhaler). Observing the inhalation technique was valuable however this misses suboptimal PIF (approaching one fourth of patients with a satisfactory observed manoeuvre had a suboptimal PIF for their DPI). Assess adherence as deliberate non-adherence can point to a mismatch between a patient and their inhaler (deliberate non-adherence was significantly associated with PIFs below the minimum for the DPI). In-person observation of inhalation technique was found to be inferior to video rating based on device-specific checklists. Where video assessments are not possible, observation training for healthcare professionals would therefore be valuable particularly to improve the ability to identify the critical errors associated with health status namely 'teeth and lips sealed around mouthpiece', 'breathe in' and 'breathing out calmly after inhalation'. However, it is recommended that observation alone should not replace PIF measurement in the DPI selection process.

Datos de la publicación

ISSN/ISSNe:
2055-1010, 2055-1010

NPJ PRIMARY CARE RESPIRATORY MEDICINE  NATURE PUBLISHING GROUP

Tipo:
Article
Páginas:
-
PubMed:
36575175

Citas Recibidas en Web of Science: 25

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Campos de Estudio

Cita

Compartir