New 3-Dimensional Volumetric Ultrasound Method for Accurate Quantification of Atherosclerotic Plaque Volume

Fecha de publicación: Fecha Ahead of Print:

Autores de IdISBa

Autores ajenos a IdISBa

  • Lopez-Melgar, B
  • Mass, V
  • Nogales, P
  • Sanchez-Gonzalez, J
  • Entrekin, R
  • Collet-Billon, A
  • Fernandez-Friera, L
  • Fernandez-Ortiz, A
  • Sanz, J
  • Bentzon, JF
  • Bueno, H
  • Ibanez, B
  • Fuster, V

Grupos de Investigación

Abstract

BACKGROUND: Carotid and femoral plaque burden is a recognized biomarker of cardiovascular disease risk. A new electronic-sweep 3-dimensional (3D)-matrix transducer method can improve the functionality and image quality of vascular ultrasound atherosclerosis imaging. OBJECTIVES: This study aimed to validate this method for plaque volume measurement in early and intermediate-advanced plaques in the carotid and femoral territories. METHODS: Plaque volumes were measured ex vivo in pig carotid and femoral artery specimens by 3-dimensional vascular ultrasound (3DVUS) using a 3D-matrix (electronic-sweep) transducer and its associated 3D plaque quantification software, and were compared with gold-standard histology. To test the clinical feasibility and accuracy of the 3D-matrix transducer, an experiment was conducted in intermediate-high risk individuals with carotid and femoral atherosclerosis. The results were compared with those obtained using the previously validated mechanical-sweep 3D transducer and established 2-dimensional (2D)-based plaque quantification software. RESULTS: In the ex vivo study, the authors assessed 19 atherosclerotic plaques (plaque volume, 0.76 mu L-56.30 mu L), finding strong agreement between measurements with the 3D-matrix transducer and the histological gold-standard (intraclass correlation coefficient [ICC]: 0.992; [95% CI: 0.978-0.997]). In the clinical analysis of 20 patients (mean age 74.6 +/- 4.45 years; 40% men), the authors found 64 (36 carotid and 28 femoral) of 80 scanned territories with atherosclerosis (measured atherosclerotic volume, 10 mu L-859 mu L). There was strong agreement between measurements made from electronic-sweep and mechanical-sweep 3DVUS transducers (ICC: 0.997 [95% CI: 0.995-0.998]). Agreement was also high between plaque volumes estimated by the 2D and 3D plaque quantification software applications (ICC: 0.999 [95% CI: 0.998-0.999]). Analysis time was significantly shorter with the 3D plaque quantification software than with the 2D multislice approach with a mean time reduction of 46%. CONCLUSIONS: 3DVUS using new matrix transducer technology, together with improved 3D plaque quantification software, simplifies the accurate volume measurement of early (small) and intermediate-advanced plaques located in carotid and femoral arteries. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.

Datos de la publicación

ISSN/ISSNe:
1936-878X, 1876-7591

JACC. Cardiovascular imaging  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1124-1135
PubMed:
35680220

Citas Recibidas en Web of Science: 22

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • accuracy; atherosclerotic plaque; gold-standard; plaque volume; three-dimensional; vascular ultrasound