Prognosis of Paradoxical Low-Flow Low-Gradient Aortic Stenosis: A Severe, Non-critical Form, With Surgical Treatment Benefits

Fecha de publicación:

Autores de IdISBa

Autores ajenos a IdISBa

  • Galian-Gay, L
  • Escalona Silva RA
  • Teixido-Tura, G
  • Casas, G
  • Ferrer-Sistach, E
  • Mitroi, C
  • Mingo, S
  • Monivas, V
  • Saura, D
  • Vidal, B
  • Trasca, L
  • Moral, S
  • Calvo, F
  • Castiñeira Busto M
  • Sanchez, V
  • Gonzalez, A
  • Guzman, G
  • Arnau Vives M
  • Peteiro, J
  • Bouzas, A
  • Mas-Stachurska, A
  • Gonzalez-Alujas, T
  • Gutierrez, L
  • Fernandez-Galera, R
  • Valente, F
  • Guala, A
  • Ruiz-Munoz, A
  • Avilés CAS
  • Palomares JFR
  • Ferreira, I
  • Evangelista, A

Grupos de Investigación

Abstract

ObjectivesTo determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS). MethodsA longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm(2)) and normal left ventricular ejection fraction (LVEF). Patients were classified as: high-gradient (HG, mean gradient >= 40 mmHg), normal-flow low-gradient (NFLG, mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35 ml/m(2)) and LFLG (mean gradient < 40 mmHg, SVi <= 35 ml/m(2)). ResultsOf 1,391 patients, 147 (10.5%) had LFLG, 752 (54.1%) HG, and 492 (35.4%) NFLG. Echocardiographic parameters of the LFLG group showed similar AVA to the HG group but with less severity in the dimensionless index, calcification, and hypertrophy. The HG group required AVR earlier than NFLG (p < 0.001) and LFLG (p < 0.001), with no differences between LFLG and NFLG groups (p = 0.358). Overall mortality was 27.7% (CI 95% 25.3-30.1) with no differences among groups (p = 0.319). The impact of AVR in terms of overall mortality reduction was observed the most in patients with HG (hazard ratio [HR]: 0.17; 95% CI: 0.12-0.23; p < 0.001), followed by patients with LFLG (HR: 0.25; 95% CI: 0.13-0.49; p < 0.001), and finally patients with NFLG (HR: 0.29; 95% CI: 0.20-0.44; p < 0.001), with a risk reduction of 84, 75, and 71%, respectively. ConclusionsParadoxical LFLG AS affects 10.5% of severe AS, and has a lower need for AVR than the HG group and similar to the NFLG group, with no differences in mortality. AVR had a lower impact on LFLG AS compared with HG AS. Therefore, the findings of the present study showed LFLG AS to have an intermediate clinical risk profile between the HG and NFHG groups.

Datos de la publicación

ISSN/ISSNe:
2297-055X,

Frontiers in Cardiovascular Medicine  FRONTIERS MEDIA SA

Tipo:
Article
Páginas:
852954-852954
PubMed:
35433871

Citas Recibidas en Web of Science: 4

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • aortic stenosis; paradoxical low-flow low-gradient; echocardiography; aortic valve surgery; heart valve disease

Campos de Estudio

Cita

Compartir