Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale
Fecha de publicación:
Autores de IdISBa
Autores ajenos a IdISBa
- Schroder, H
- Subirana, I
- Warnberg, J
- Medrano, M
- Gonzalez-Gross, M
- Gusi, N
- Aznar, S
- Alcaraz, PE
- Gonzalez-Valeiro, MA
- Serra-Majem, L
- Terrados, N
- Segu, M
- Homs, C
- Garcia-Alvarez, A
- Benavente-Marin, JC
- Baron-Lopez, FJ
- Labayen, I
- Zapico, AG
- Sanchez-Gomez, J
- Jimenez-Zazo, F
- Marin-Cascales, E
- Sevilla-Sanchez, M
- Herrera-Ramos, E
- Pulgar, S
- Sistac-Sorigue, C
- Gomez, SF
Grupos de Investigación
Abstract
Background Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested. Methods A randomized sample of 321 healthy children aged 8-16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation. Results The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 +/- 77.0 vs 95.2 +/- 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (beta - 0.162; p < 0.077) and waist to height ratio (beta - 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls. Conclusion The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents.
Datos de la publicación
- ISSN/ISSNe:
- 1479-5868, 1479-5868
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 34274002
International Journal Of Behavioral Nutrition And Physical Activity BIOMED CENTRAL LTD
Citas Recibidas en Web of Science: 28
Documentos
- No hay documentos
Filiaciones
Keywords
- Children and adolescents; Self-reported physical activity; Short PAQ; Validation; Accelerometry
Campos de Estudio
Cita
Schroder H; Subirana I; Warnberg J; Medrano M; Gonzalez Gross M; Gusi N; Aznar S; Alcaraz PE; Gonzalez Valeiro MA; Serra Majem L; Terrados N; Tur JA; Segu M; Homs C; Garcia Alvarez A; Benavente Marin JC; Baron Lopez FJ; Labayen I; Zapico AG; Sanchez Gomez J; Jimenez Zazo F; Marin Cascales E; Sevilla Sanchez M; Herrera Ramos E; Pulgar S; Bibiloni MD; Sistac Sorigue C; Gomez SF. Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale. International Journal Of Behavioral Nutrition And Physical Activity. 2021. 18 (1):
Portal de investigación