Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale

Fecha de publicación:

Autores de IdISBa

Autores ajenos a IdISBa

  • Schroder, H
  • Subirana, I
  • Warnberg, J
  • Medrano, M
  • Gonzalez-Gross, M
  • Gusi, N
  • Aznar, S
  • Alcaraz, PE
  • Gonzalez-Valeiro, MA
  • Serra-Majem, L
  • Terrados, N
  • Segu, M
  • Homs, C
  • Garcia-Alvarez, A
  • Benavente-Marin, JC
  • Baron-Lopez, FJ
  • Labayen, I
  • Zapico, AG
  • Sanchez-Gomez, J
  • Jimenez-Zazo, F
  • Marin-Cascales, E
  • Sevilla-Sanchez, M
  • Herrera-Ramos, E
  • Pulgar, S
  • Sistac-Sorigue, C
  • Gomez, SF

Grupos de Investigación

Abstract

Background Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested. Methods A randomized sample of 321 healthy children aged 8-16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation. Results The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 +/- 77.0 vs 95.2 +/- 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (beta - 0.162; p < 0.077) and waist to height ratio (beta - 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls. Conclusion The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents.

Datos de la publicación

ISSN/ISSNe:
1479-5868, 1479-5868

International Journal Of Behavioral Nutrition And Physical Activity  BIOMED CENTRAL LTD

Tipo:
Article
Páginas:
-
PubMed:
34274002

Citas Recibidas en Web of Science: 28

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Children and adolescents; Self-reported physical activity; Short PAQ; Validation; Accelerometry

Campos de Estudio

Cita

Compartir