Statistical control of processes applied to geometric uncertainties for CTV expansion margins determination in prostate cancer patients treated with VMAT: a prospective study in 57 patients

Fecha de publicación: Fecha Ahead of Print:

Autores de IdISBa

  • Jose Pardo Masferrer

    Autor

  • Neus Aymar Salís

    Autor

  • Irene Ortiz González

    Autor

  • Araceli Guerrero Grande

    Autor

  • Ana Maria Mena Merino

    Autor

Autores ajenos a IdISBa

  • Gonzalez, J
  • Rodriguez, B
  • Morera, D
  • Font, J

Abstract

Purpose To study the control graphs applicability for the geometric uncertainties of VMAT treatments in prostate cancer patients, and their use to verify the hypothesis of the data obtained randomness, to apply the margins of Van Herk expression. Material and methods During the first 5 days of treatment, and then once a week, a Kv CBCT was performed, compared with the simulation CT and adjusted the displacements, to determine the inter-fraction errors. Immediately after radiation therapy, another CBCT was performed (for intra-fraction errors). With these data, theX,Rposition control charts have been made. The patients, not maintained the deviations within the charts control limits, were called "anomalies". Then, we compared the deviations and margins calculated with the van Herk expression for all patients and for those without anomalies. Results The margins determined show appreciable differences if there were calculated for the total set of patients or for the set of them without anomalies in the control charts. For the overall set of patients, the lateral, longitudinal, and vertical margins were 0.45 cm, 0.52 cm, 0.56 cm, while for the set of patients without anomalies were 0.29 cm, 0.35 cm, and 0.38 cm. Conclusions The use of control charts allows tracking geometric deviations both inter and intra-fraction, variability real-time control and to detect situations in which it can change for non-random reasons, and require immediate investigation. Maintaining geometric deviations in the control state decreases the margins needed to administer a high dose to CTV in a high percentage of cancer prostate patients.

Datos de la publicación

ISSN/ISSNe:
1699-048X, 1699-3055

CLINICAL & TRANSLATIONAL ONCOLOGY  SPRINGER-VERLAG ITALIA SRL

Tipo:
Article
Páginas:
1078-1084
PubMed:
32981004

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • VMAT treatments uncertainties; Prostate cancer patients; Control state of geometric deviations; Control charts

Campos de Estudio

Cita

Compartir