Nosocomial outbreak linked to a flexible gastrointestinal endoscope contaminated with an amikacin-resistant ST17 clone of Pseudomonas aeruginosa

Fecha de publicación: Fecha Ahead of Print:

Autores de IdISBa

Autores ajenos a IdISBa

  • Fernandez-Cuenca, Felipe
  • Lopez-Cerero, Lorena
  • Lopez-Mendez, Julio
  • Recacha, Esther
  • Portillo, Ines
  • Rodriguez-Bano, Jesus
  • Pascual, Alvaro

Grupos de Investigación

Abstract

Endoscope contamination is infrequent but can be the source of nosocomial infections and outbreaks. In August 2016, an unexpected increase in the incidence of amikacin-resistant P. aeruginosa isolates (AK-Pae) was observed at a tertiary care center in the south of Spain. An epidemiological and microbiological investigation (August-October 2016) was performed to explain this finding. Isolates from clinical and environmental samples (2 endoscopes used for retrograde cholangiopancreatography; ERCP) were identified by MALDI-TOF. Antimicrobial susceptibility testing was performed using the MicroScan system. Whole-Genome-Sequencing (Miseq, Illumina) was performed to determine the resistome and virulome. Clonal relatedness among isolates was assessed by SpeI-PFGE and MLST. A Caenorhabditis elegans killing assay was performed for virulence testing. Biofilm formation was performed using a colorimetric assay. Four of the 5 patients infected and/or colonized with AK-Pae in August 2016 had undergone ERCP <= 5 days before sample collection. Two endoscopes were contaminated with AK-Pae. Isolates from one endoscope showed an identical PFGE pattern to 9 isolates (cluster I) and differed (1-2 bands) to 5 isolates (cluster II). Isolates from these clusters belonged to the ST17 clone. This S17 clone was characterized by its low virulence in the C. elegans killing assay, and its biofilm-forming ability, slightly superior to that of high-risk clones of P. aeruginosa ST175 and ST235. This outbreak was caused by an endoscope used for ERCP contaminated with an invasive, moderately virulent, biofilm-forming AK-Pae ST17 clone, suggesting the possible emergence of a new high-risk lineage of this clone.

Datos de la publicación

ISSN/ISSNe:
0934-9723, 1435-4373

EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES  SPRINGER

Tipo:
Article
Páginas:
1837-1844
PubMed:
32372127

Citas Recibidas en Web of Science: 12

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Outbreak; Endoscope; Pseudomonas aeruginosa; ST17 clone

Campos de Estudio

Cita

Compartir