Development of a thin layer chromatography method for plasma correction of [F-18]fluorocholine metabolites in positron emission tomography quantification studies in humans
Autores de IdISBa
Autores ajenos a IdISBa
- Valiente, M
- Toscano, M
- Galmes, M
- Gonzalez, C
- Ortiz, M
- Vega, F
- Oporto, M
- Chinchilla, JL
Grupos de Investigación
Abstract
Introduction: After its intravenous injection, [F-18]fluorocholine is oxidized by choline-oxidase into its main plasma metabolite, [F-18]fluorobetaine. If PET kinetic modeling quantification of [F-18]fluorocholine uptake is intended, the plasma input time-activity-curve of the parent tracer must be obtained, i.e., the fraction of the total plasma radioactivity corresponding to the nonmetabolized [F-18]fluorocholine at each time has to be known. Hence our aim was to develop an easy-routine Thin-Layer-Chromatography (TLC) method to separate and quantify the relative fractions of [F-18]fluorocholine and [F-18]fluorobetaine as a function of time during PET imaging in humans. Methods: First, we tested several combinations of solvents systems and layers to select the one showing the best resolution on non-radioactive standards. Thereafter, [F-18]fluorobetaine was obtained through chemical oxidation of an [F-18]fluorocholine sample at diferent incubation times and we applied the selected TLC-system to aliquots of this oxidation solution, both in a saline and in human deproteinized plasma matrices. The plates were detected by a radio-TLC-scanner. This TLC-system was finally applied to arterial plasma samples from 9 patients with highgrade-glioma undergoing brain PET imaging and a parent fraction curve was obtained in each of them. Results: A TLC-system based on Silica-Gel-60//MeOH-NH3 was selected from the choline/betaine non-radioactive standards assay. Radiochromatograms of [F-18]fluorocholine oxidation solution yielded two separated and well-defined peaks, Rf = 0,03 ([F-18]fluorocholine) and Rf = 0.78 (F-18]fluorobetaine) consistent with those observed on non-radioactive standards. During the oxidation, [F-18]fluorocholine radioactivity peak decreased progressively at several incubation times, while the other peak [F-18]fluorobetaine) increased accordingly. The mean values of the parent fraction of [F-18]fluorocholine of the 9 patients studied (mean+/-SD) were 94% +/- 6%, 58% +/- 15%, 43% +/- 10%, 39% +/- 6% and 37% +/- 6% at 2.8 min, 5.8 min, 8.8 min, 11.7 min and 14.7 min post-injection, respectively. Conclusions: We have developed a TLC-system, easy to perform in a standard radiopharmacy unit, that enables the metabolite correction of arterial input function of [F-18]fluorocholine in patients undergoing PET oncologic quantitative imaging. (C) 2019 Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0969-8051, 1872-9614
- Tipo:
- Article
- Páginas:
- 34-40
- PubMed:
- 31473490
Nuclear Medicine And Biology Elsevier BV
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- TLC; Dynamic PET; Kinetics; [F-18]fluorocholine; Betaine; Metabolism
Cita
Villar M; Valiente M; Toscano M; Galmes M; Gonzalez C; Ortiz M; Vega F; Oporto M; Bibiloni P; Chinchilla JL; Molina J; Rios A; Pena C; Rubi S. Development of a thin layer chromatography method for plasma correction of [F-18]fluorocholine metabolites in positron emission tomography quantification studies in humans. Nuclear Medicine And Biology. 2019. 74-7534-40.