Sample-dependent diagnostic accuracy of prostaglandin D synthase in cerebrospinal fluid leak
Autores de IdISBa
Autores ajenos a IdISBa
- Sastre, MP
Grupos de Investigación
Abstract
Background: Prostaglandin D2 synthase, commonly known as beta-trace protein (beta TP), is an excellent biomarker for the assessment of cerebrospinal fluid (CSF) leaks. Despite being widely used, the limits for the diagnostic values of beta TP are not well established to date, and currently suggested cut-off values in literature range from 0.25 to 6.0 mg/L. Sample-specific and more accurate thresholds are a current need. Methods: A retrospective observational study, performed in a tertiary-care hospital, between January 2006 and January 2014. A total of 74 patients were included, with a definitive diagnosis after initial leak suspicion and at least one determination of beta TP using a nephelometry-based assay.A total of 46 CSF samples were included in the control group. Samples were obtained from nasal secretions, ear secretions or spinal surgical injury, directly using sterile Eppendorf tubes. The analysis of 3 different cut-off values was performed and the receiver operating curve (ROC) analyses were calculated. Results: Initial diagnostic suspicion was confirmed in 51% of cases, most of which were of postoperative origin (51%) and traumatic (26%). The beta TP median concentration in different samples was significantly higher in the presence of cerebrospinal fluid fistula, regardless of sample type (22.0 mg/L'vs. 024 mg/I, 95% confidence interval: 19.0-30.8 vs. 0.08-0.40; p < 0.001). Data from contingency tables show 100% sensitivity and specificity, depending on sample type and the cut-off value used: for rhinorrhea and otorrhea samples, the most appropriate it was 0.7 mg/L, while values >2.0 mg/L could be used for spine postoperative fluid leakage samples. Conclusions: The cut off value for beta TP in the diagnosis and follow-up of cerebrospinal fluid leaks should be modified depending on the type of Secretion (sample type), for a better diagnostic accuracy. (C) 2016 The Canadian society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0009-9120, 1873-2933
- Tipo:
- Article
- Páginas:
- 27-31
- PubMed:
- 27614217
Clinical Biochemistry PERGAMON-ELSEVIER SCIENCE LTD
Citas Recibidas en Web of Science: 8
Documentos
- No hay documentos
Filiaciones
Keywords
- Beta-trace protein; Cerebrospinal fluid leak; Cut-off; Nephelometry; Rhinorrhea
Campos de Estudio
Cita
Morell Garcia D; Bauca JM; Sastre MP; Yanez A; Llompart I. Sample-dependent diagnostic accuracy of prostaglandin D synthase in cerebrospinal fluid leak. Clinical Biochemistry. 2017. 50 (1-2): 27-31.
Portal de investigación