Cross-Reactivity of Chloroquine and Hydroxychloroquine With DRI Amphetamine Immunoassay
Autores de IdISBa
Autores ajenos a IdISBa
- Fernandez, J
- Servera, MA
- Sahuquillo, L
- Dastis, M
- Torrents, A
Grupos de Investigación
Abstract
Background: Chloroquine and hydroxychloroquine are medical drugs used to treat the chemoprophylaxis of malaria and a second-line anti-inflammatory drug. Methods: We performed a study of cross-reactivity of chloroquine and hydroxychloroquine in the DRI Amphetamine Assay inspired by a case report of a self-ingestion of chloroquine after a family dispute, that involved the following: (1) an in vitro study with control samples of healthy subjects, (2) an in vivo study with samples of patients with rheumatoid arthritis, and (3) an evaluation of the cross-reactivity of chloroquine and hydroxychloroquine in 3 additional immunoassays. Results: In the case report, the Amphetamine DRI assay resulted positive both at 1000 ng/mL cutoff (1507 and 1137 ng/mL) and at 500 ng/mL cutoff (1178 and 642 ng/mL). Chloroquine urine levels were 103,900 and 100,900 ng/mL at 5 and 9 hours after ingestion. The results with control samples showed a positive cross-reactivity of chloroquine in the DRI Amphetamine Assay (approximately 0.74% and 0.89% at cutoff of 1000 and 500 ng/mL, respectively). Hydroxychloroquine did not cross-react with the DRI Amphetamine Assay up to 1,000,000 ng/mL. In patients treated with chloroquine or hydroxychloroquine, DRI Amphetamine did not produce false-positive results. The comparative assay study showed a positive cross-reactivity of chloroquine in the Emit II Plus Amphetamines Assay with control samples. Conclusions: Chloroquine can cause false-positive results in the DRI Amphetamine Assay when it is present at high concentrations. Hydroxychloroquine did not produce false-positive results neither in the DRI Amphetamine Assay nor in the others immunoassays evaluated.
Datos de la publicación
- ISSN/ISSNe:
- 0163-4356, 1536-3694
- Tipo:
- Article
- Páginas:
- 192-196
- PubMed:
- 28207572
Therapeutic Drug Monitoring LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 8
Documentos
- No hay documentos
Filiaciones
Keywords
- chloroquine; hydroxychloroquine; urine drug screen; amphetamine immunoassay; cross-reactivity
Campos de Estudio
Cita
Gomila I; Quesada L; Lopez Corominas V; Fernandez J; Servera MA; Sahuquillo L; Dastis M; Torrents A; Barcelo B. Cross-Reactivity of Chloroquine and Hydroxychloroquine With DRI Amphetamine Immunoassay. Therapeutic Drug Monitoring. 2017. 39 (2): 192-196.
Portal de investigación